Thursday, December 19, 2013

Frozen cold sample homogenizing

Need to homogenize a frozen or cold sample? Worried about your sample denaturing?

It sure is cold out there...but don't worry our homogenizers LOVE the cold.


Need to homogenize a frozen or cold sample?
Worried about your sample denaturing?

Our PRO Homogenizers love the cold!

Unlike sonication and bead-beating homogenization techniques, our mechanical, rotor stator generators probes can quickly and effectively process your cold or frozen sample in mere seconds without producing heat.  


The tip is to choose a PRO generators probe that is best for your sample size, type and tube.
Frozen Sample Applications
Let's get started choosing a homogenizer
All of our PRO Generator probes are precision crafted with a very narrow clearance between the inner rotating shaft and outer tube/chamber. This allows for quick, effective and repetitive homogenizing, meaning you will get the results you want each and every time.
It is important to note that a liquid medium such as a reagent or buffer will need to be added to the frozen or cold sample in order to maintain proper operation of the PRO Homogenizing Equipment.
Need more help selecting a homogenizer package?

Request a Quote
LinkedIn
LinkedIn
Twitter
Twitter
Facebook
Facebook
YouTube
YouTube
Blog
Blog
Email
Email
Website
Website

Tuesday, December 10, 2013

Choosing a Homogenizer Package is as Easy as 1,2,3 - Micro, MaX, Universal and Multi-Sample!

Choosing a Homogenizer Package, 

Micro, MaX, Universal and Multi-Sample!


Is as easy as....

1. Download the sales flier.

Download Homogenizer Package Flier

2. Use our flow-through chart selection guide to choose the package that best suits your customer's needs.

3. See our homogenizer packages in action!

Homogenize in tubes from .5ml up to 50ml with our Micro-Homogenizing Packages!
Avoid cross-contamination with our Multi-Gen 7XL Homogenizing Packages!
Need more help selecting a package?
  • All packages now come with a PRO Carrying Case

  • Keep your valuable equipment safe

  • Share equipment easier within labs

  • Keep all your homogenizing accessories in one place


Request a Quote
LinkedIn
LinkedIn
Twitter
Twitter
Facebook
Facebook
YouTube
YouTube
Blog
Blog
Email
Email
Website
Website

Monday, December 2, 2013

The Field of Homogenizing: Mechanical, Ultrasonic & Pressure Homogenizers

PRO Scientific Homogenizers

Click for Individual Webpage


Bio-Gen PRO200 Homogenizer
Bio-Gen PRO200 Homogenizer
















High Power PRO250 Homogenizer
PRO250 Homogenizer

D Series Benchtop Homogenizer
D-Series Benchtop Homogenizer




THE FIELD OF HOMOGENIZING

The field of homogenizing encompasses a very broad area. The word homogenize means "to make or render homogeneous" while homogeneous means "having the same composition, structure, or character throughout". Homogenizing is what is called an umbrella word - a word which covers a very large area. When someone says that they are homogenizing, they may mean that they are actually doing one or more of the following, blending, mixing, disrupting, emulsifying, dispersing, stirring etc. Therefore during this writing when the word homogenizing is used it may mean any one or more of the above mentioned processes.
The current processes or methods of homogenizing can be broken down into three (3) major categories, mechanical, ultrasonic and pressure.

MECHANICAL HOMOGENIZERS

Mechanical homogenizers can be broken down into two (2) separate categories, rotor-stator homogenizers and blade type homogenizers.

Rotor-stator homogenizers (also called colloid mills or Willems homogenizers) generally outperform cutting blade-type blenders and are well suited for plant and animal tissue. Combined with glass beads, the rotor-stator homogenizer has been successfully used to disrupt microorganisms. However, the homogenized sample is contaminated with minute glass and stainless steel particles and the abrasive wear to the rotor-stator homogenizer is unacceptably high. Cell disruption with the rotor-stator homogenizer involves hydraulic and mechanical shear as well as cavitation. Some people in the homogenizing field also claim that there is to a lesser extent high-energy sonic and ultrasonic pressure gradients involved.
I personally do not believe in the theory that high-energy sonic and ultrasonic pressure gradients are involved with mechanical homogenizers. The only thing that ultrasonic and mechanical (rotor-stator) homogenizing have in common is that both methods generate and use to some degree cavitation. Cavitation is defined as the formation and collapse of low-pressure vapor cavities in a flowing liquid. Cavitation is generated as you move a solid object through a liquid at a high rate of speed. In ultrasonics the object being moved is the probe which is being vibrated at a very high rate of speed generating cavitation. In mechanical homogenizing (rotor-stator) the blade (rotor) is being moved through the liquid at a high rate of speed generating cavitation.
The rotor-stator generator type homogenizer was first developed to make dispersions and emulsions, and most biological tissues are quickly and thoroughly homogenized with this apparatus. Appropriately sized cellular material is drawn up into the apparatus by a rapidly rotating rotor (blade) positioned within a static head or tube (stator) containing slots or holes. There the material is centrifugally thrown outward in a pump like fashion to exit through the slots or holes. Because the rotor (blade) turns at a very high rpm, the tissue is rapidly reduced in size by a combination of extreme turbulence, cavitation and scissor like mechanical shearing occurring within the narrow gap between the rotor and the stator. Since most rotor-stator homogenizers have an open configuration, the product is repeatedly recirculated. The process is fast and depending on the toughness of the tissue sample, desired results will usually be obtained in 15-120 seconds. For the recovery of intracellular organelles or receptor site complexes, shorter times are used and the rotor speed is reduced. The variables to be optimized for maximum efficiency are as follows:
  •  Design and size of rotor-stator (generator)
  •  Rotor tip speed Initial size of sample 
  • Viscosity of medium Time of processing or flow rate 
  • Volume of medium and concentration of sample 
  • Shape of vessel and positioning of rotor-stator

The size of the rotor-stator probe (also called generator) can vary from the diameter of a pencil for 0.01-10mI sample volumes to much larger units having batch capacities up to 19,000 liters or, for on-line units, capabilities of 68,000 liters/hr. Rotor speeds vary from 3,000 rpm for large units to 8,000-60,000 rpm for the smaller units. In principle, the rotor speed of the homogenizer should be doubled for each halving of the rotor diameter. It is not the rpm's of the motor but the tip velocity of the rotor that is the important operating parameter. Other factors such as rotor-stator design, which there are many, materials used in construction, and ease of leaning are also important factors to consider in selecting a rotor-stator homogenizer.
.
Generator
Maximum Speed
11p Speed (Meters/second)
02-05075
28,000 rpm
6
02-07075
28,000 rpm
9
02-10150
28.000 rpm
12
02-20150
28,000 rpm
25
02-30150
28,000 rpm
35
02-37150
20,000 rpm
30
02-43150
20,000 rpm
37
02-59150
20,000 rpm
54

Laboratory size rotor-stator homogenizers process liquid samples in the 0.01 ml to 20 liter range. The capacity of the rotor-stator should be matched to the viscosity and volume of the medium and with the type and amount of plant and animal tissue to be processed. The speed and efficiency of homogenization is greatly degraded by using too small a homogenizer, and the volume range over which a given homogenizer rotor-stator size will function efficiently is only about 10 fold. Also, most of the laboratory-sized homogenizers function properly only with liquid samples in the low to medium viscosity range (<10,000 cps). This must be balanced against the practical observation that concentrated samples, by colliding more frequently, are broken up more rapidly. Higher viscosity samples can be processed but require specially shaped homogenization vessels or unique rotor-stator configurations. The size of the sample prior to processing with the homogenizer must be small enough to be drawn inside the stator. Therefore, samples often must be pre-chopped, cut or fragmented.
Foaming and aerosols can be a problem with rotor-stator homogenizers. Keeping the tip of the homogenizer well submerged within the media and the use of properly sized vessels helps with the first problem. Square-shaped or fluted vessels give better results than round vessels and it is also beneficial to hold the immersed tip off center. Aerosols can be minimized by using covered vessels. Pro Scientific offers a complete line of Safety Sealed chambers which eliminate the aerosoling problem. The most widely used Safety Sealed chambers are those of the ST series. The ST series uses four different size standard laboratory test tubes and incases them within a sealed cage. The four units currently in the ST series are as follows:


There are no aerosols with in-line homogenizers. Even though a number of the laboratory rotor-stator homogenizers use sealed motors, none of them are truly explosion-proof. Due caution should be followed when using flammable organic solvents by conducting the homogenization in a well ventilated hood. On the positive side, rotor-stator homogenizers generate minimal heat during operation and this can be easily dissipated by cooling the homogenization vessel in ice water during processing.
The larger rotor-stator homogenizers are either scaled up versions of the laboratory models or in-line homogenizers. The latter contain teeth on the edge of a horizontally oriented, multi-bladed, high-speed impeller aligned in close tolerance to matching teeth in a static liner.

Although less efficient than rotor-stator homogenizers, blade homogenizers (also called blenders) have been used for many years to produce fine brie and extracts from plant and animal tissue. The cutting blades on this class of homogenizer are either bottom or top driven and rotate at speeds of 6,000 to 50,000 rpm. Blenders are not suitable for disruption of microorganisms unless glass beads or other abrasives are added to the media and then one encounters the same problems as were mentioned above for rotor-stator homogenizers. Many plant tissue homogenizers undergo enzymatic browning which is a biochemical oxidation process which can complicate subsequent separation procedures. Enzymatic browning is minimized by carrying out the extraction in the absence of oxygen or in the presence of thiol compounds such as mercaptoethanol. Sometimes addition of polyethylene imine, metal chelators, or detergents such as Triton X-100 or Tween-80 also helps.
Blade homogenizers are available for a range of liquid sample sizes from 0.01 ml to multi gallons. Some of the higher rpm homogenizers can reduce tissue samples to a consistent particulate size with distributions as small as 4um as determined by flow cytometric analysis. Accessories for some blenders include cooling jackets to control temperature and closed containers to minimize aerosol formation and entrainment of air. PRO Scientific has a complete line of Safety Sealed chambers which eliminates the aerosoling problem as well as the problem of introducing air into the sample.

ULTRASONIC HOMOGENIZING

One widely used method to disrupt cells is ultrasonic disruption. These devices work by generating intense sonic pressure waves in a liquid media. The pressure waves cause streaming in the liquid and, under the right conditions, rapid formation of micro-bubbles which grow and coalesce until they reach their resonant size, vibrate violently, and eventually collapse. This phenomenon is called cavitation. The implosion of the vapor phase bubbles generates a shock wave with sufficient energy to break covalent bonds. Shear from the imploding cavitation bubbles as well as from eddying induced by the vibrating sonic transducer disrupt cells.
There are several external variables which must be optimized to achieve efficient cell disruption. These variables are as follows:
  • Tip amplitude and intensity 
  • Temperature 
  • Cell concentration 
  • Pressure 
  • Vessel capacity and shape

Modem ultrasonic processors use piezoelectric generators made of lead zirconate titanate crystals. The vibrations are transmitted down a titanium metal horn or probe tuned to make the processor unit resonate at 15-25 kHz. The rated power of ultrasonic processors vary from 10 to 375 Watts. low power output does not necessarily mean that the cell disintegrator is less powerful because lower power transducers are generally matched to probes having smaller tips. It is the power density at the tip that counts. Higher output power is required to maintain the desired amplitude and intensity under conditions of increased load such as high viscosity or pressure. The larger the horn, the more power is required to drive it and the larger the volume of sample that can he processed. On the other hand, larger ultrasonic disintegrators generate considerable heat during operation and will necessitate aggressive external cooling of the sample. Typical maximum tip amplitudes are 30-250 urn and resultant output intensities are in the range of 200-2000 W/square cm.
The temperature of the sample suspension should be as low as possible. In addition to addressing the usual concerns about temperature lability of proteins, low media temperatures promote high-intensity shock front propagation. So ideally, the temperature of the ultrasonicated fluid should be kept just above its freezing point. The ultrasonic disintegrator generates considerable heat during processing and this complicates matters. Disruption can also be enhanced by increased hydrostatic pressure (typically 15-60 psi) and increased viscosity, providing the ultrasonic processor has sufficient power to overcome the increased load demand and the associated sample heating problems can be solved. For microorganisms the addition of glass beads in the 0.05 to 0.5mm size range enhances cell disruption by focusing energy released by the bubble implosions and by physical crushing. Beads are almost essential for disruption of spores and yeast. A good ratio is one volume of beads to two volumes of liquid. Tough tissues such as skin and muscle should be macerated first in a blender or the like and confined to a small vessel during ultrasonic treatment. The tip should not be placed so shallow in the vessel as to allow foaming. Antifoaming agents or other materials which lower surface tension should be avoided. Finally, one must keep in mind that free radicals are formed in ultrasonic processes and that they are capable of reading with biological material such as proteins, polysaccharides, or nucleic acids. Damage by oxidatire free radicals can be minimized by including scavengers like cysteine, dithiothreitol, or other SH compounds in the media or by saturating the sample with a protective atmosphere of helium or hydrogen gas.
For practical reasons, the tip diameter of ultrasonic horns cannot exceed about 3 inches. This sets a limit on the scale-up of these devices. While standard sized ultrasonic disrupters have been adapted to continuous operation by placing the probe tip in a chamber through which a stream of cells flow, cooling and free radical release present problems.

PRESSURE HOMOGENIZING

High-pressure homogenizers have been used to disrupt microbial cells for many years. With the exception of highly filamentous microorganisms, the method has been found to be generally suitable for a variety of bacteria, yeast and mycelia.
This type of homogenizer works by forcing cell suspensions through a very narrow channel or orifice under pressure. Subsequently, and depending on the type of high-pressure homogenizer, they may or may not impinge at high velocity on a hard-impact ring or against another high-velocity stream of cells coming from the opposite direction. Machines which include the impingement design are more effective than those which do not. Disruption of the cell wall occurs by a combination of the large pressure drop, highly focused turbulent eddies, and strong shearing forces. The rate of cell disruption is proportional to approximately the third power of the turbulent velocity of the product flowing through the homogenizer channel, which in turn is directly proportional to the applied pressure. Thus, the higher the pressure, the higher the efficiency of disruption per pass through the machine. The operating parameters which effect the efficiency of high-pressure homogenizers are as follows:
  • Pressure
  • Temperature
  • Number of passes
  • Valve and impingement design
  • Flow rate

High-pressure homogenizers have long been the best available means to mechanically disrupt nonfilamentous microorganisms on a large scale. Animal tissue also can be processed but the tissue must be pretreated with a blade blender, rotor-stator homogenizer, or paddle blender. The supremacy of high-pressure homogenizers for disruption of microorganisms is now being challenged by bead mill homogenizers. Still, in terms of throughput, the largest industrial models of high-pressure homogenizers outperform bead mills. The maximum volume of microbial suspension per hour that can be treated by the larger commercial machines is 4,500 liters for high-pressure homogenizers versus about 1,200 liters for bead mills. Even larger capacity high-pressure homogenizers are available but their efficiency in disrupting microbial cells has not been documented. This throughput advantage is diminished somewhat by the fact that most high-pressure homogenizers require several passes of the cell suspension to achieve high levels of cell disruption whereas bead mills frequently need only one.
A familiar commercial high-pressure homogenizer for the laboratory is the French press which uses a motor-driven piston inside a steel cylinder to develop pressures up to 40,000 psi. Pressurized sample suspensions up to 35m1 are bled through a needle valve at a rate of about 1 ml/min. Because the process generates heat, the sample, piston and cylinder are usually pre-cooled. Typical pressures used to disrupt yeast are 8,000 to 10,000 psi and several passes through the press may be required for high efficiency of disruption. Generally, the higher the pressure, the fewer the passes. Pressure cells rated at 20,000 psi maximum come in capacities of 3.7 and 35m1 and there is also a 35m1 capacity cell rated at 40,000 psi.
Most high-pressure homogenizers used for homogenization were adapted from commercial equipment designed to produce emulsions and homogenates in the food and pharmaceutical industries. They combine high pressure with an impingement valve. Those with a maximum pressure rating of 10,000 psi rupture about 40% of the cells on a single pass, 60% on the second pass, and 85% after four passes. Capacities of continuous homogenizers vary from 55 to 4,500 liters/hr at 10-17% w/v cell concentrations. With the larger capacity machines several passes are needed to achieve high yields of disruption. Considerable heat can be generated during operation of these homogenizers and therefore a heat exchanger attached to the outlet port is essential.
See Also:Wikipedia Homogenize
Homogenization_(chemistry)/a